Vertical Open Air Integrated Incinerator Boiler Precise Temperature Control

Place of Origin China
Brand Name RUIDING
Certification ASME/GB/ISO/EAC(EAEU)
Model Number Special boiler
Product Details
Steam Quality Compliance Rate:
> 99%
Quick-release Interface:
Box-type Economizer Flange Seal + Slide Rail Positioning
Steam Pressure:
4.6MPa
Superheated Steam Temperature:
400℃
Temperature Fluctuation:
≤±5℃
Occupancy Optimization:
50%
Delivery Time:
2-6months
Warranty:
1 Year
HS Code:
8402190000
Highlight: 

Vertical Incinerator Boiler

,

Precise Control Incinerator Boiler

,

Precise incinerator waste heat boiler

Payment & Shipping Terms
Minimum Order Quantity
1
Price
Negotiable
Payment Terms
L/C,T/T
Product Description
Vertical Open Air Integrated Incinerator Boiler
Precise Temperature Control Special Boiler

This specialized boiler features precise temperature control for high-pressure conditions and special materials production applications.

Product Overview

This special boiler adopts a vertical open-air integrated design with the drum as the core component, vertically integrating economizer and superheater modules. The box-type quick-release interface structure enables convenient replacement and efficient maintenance of segmented modules. Through the coordinated temperature control system of water-cooled wall radiation heat exchange and superheater convection heat exchange, the stability of superheated steam output is guaranteed under high-pressure conditions, adapting to stringent requirements for precise temperature control in fine chemicals and special materials production.

Vertical Open Air Integrated Incinerator Boiler Precise Temperature Control 0
Product Features

Based on a vertical open-air integrated architecture (drum in the center + economizer/superheater vertical stacking), this boiler utilizes box-type economizer quick-release interface technology (flange seal + slide rail positioning) that allows independent replacement of second/third/fourth-stage economizer modules, reducing maintenance downtime by 70%. The multi-media collaborative temperature control system (water-cooled wall radiation heat exchange + superheater convection heat exchange) stably outputs 400℃ superheated steam under 4.6MPa high-pressure conditions, with temperature fluctuation of ≤±5℃.

Technical Specifications
Steam quality compliance rate > 99%
Integrated architecture Vertical open-air layout, central drum + economizer/superheater vertical stacking
Quick-release interface Box-type economizer flange seal + slide rail positioning
Steam pressure 4.6MPa
Superheated steam temperature 400℃
Temperature fluctuation ≤±5℃
Occupancy optimization 50%
Key Advantages
  • Minimized Maintenance System: Box module quick disassembly technology increases spare parts replacement efficiency by 3 times
  • High-Pressure Steam Stability: Dual-mode temperature compensation (PID regulation + desuperheating water redundancy) ensures steam quality compliance rate greater than 99%
  • Space-Efficient Design: Vertical layout reduces floor area by 50% compared to horizontal boilers of the same specification
Research & Development

Ruiding has established the Jiangsu Province Clean Incineration Resource Engineering Technology Center and the Key Laboratory of the JICUI-Ruidings Joint Innovation Center.

This laboratory is equipped with advanced detection equipment including ICP inductively coupled plasma emission spectrometry, atomic absorption spectrophotometry, atomic fluorescence spectrophotometry, high-temperature combustion ion chromatography analyzer, high-temperature combustion rate analyzer, and rapid equilibrium flash point tester. It possesses capabilities for heavy metal analysis, elemental analysis, off-gas calorific value analysis, ash melting point detection, incineration boiler water quality testing, sewage analysis, and volatile waste analysis.

Vertical Open Air Integrated Incinerator Boiler Precise Temperature Control 1
Company Profile

Ruiding specializes in the engineering, fabrication, construction, and commissioning services of industrial waste combustion treatment systems including thermal oxidizers (incinerators), heat recovery systems (boilers), pressurized vessels, flue gas treatment systems (DeSOX, DeNOx), and plate heat exchangers.

Ruiding holds Environmental Protection Engineering Class 2 (waste gas, waste liquid, waste solid treatment) EPC certificate, ASME Certificate, Class A boiler manufacturing license, Class A boiler installation and Revamping & Maintenance certificate, A2 designing and manufacturing certificate for pressure vessels, and GC1, GC2 pressure pipeline designing & construction certificates.

With over 250,000 square meters of building area and nearly 300 professional technical staff, Ruiding has completed more than 500 engineering projects across various domestic and international industries, with significant market share in the petrochemical sector.

Frequently Asked Questions
What is the company's main business?
Focus on the R&D, design, production, installation and commissioning of industrial three wastes (waste gas/waste liquid/solid waste) incineration treatment equipment and special boilers, and provide supporting equipment such as heat exchangers, sludge dryers, etc.
Do you have industry qualification certification?
The company has passed quality, environment, occupational health, and occupational hygiene and safety management system certifications, and holds second-level qualification for environmental protection engineering contracting, Class B special environmental engineering design, Class A boiler manufacturing qualification, Class A boiler installation, inspection and maintenance certificate, A2 pressure vessel design and manufacturing certificate, GC1, GC2 pressure pipeline design and installation certificate, and Class A environmental pollution control (waste, waste gas, waste liquid) qualification certificate.
What are the core products?
  • Waste gas incinerator: Regenerative thermal oxidation furnace (RTO), regenerative catalytic oxidation furnace (RCO), catalytic oxidation furnace (CO), high temperature thermal incinerator (TO), catalytic denitrification furnace (SCR)
  • Waste liquid incinerator: Organic waste liquid incinerator, salt-containing waste liquid incinerator, heavy component residue incinerator
  • Solid incinerator: Combined rotary kiln incinerator, gas-controlled pyrolysis incinerator, fluidized bed incinerator, step-type incinerator
  • A-level boiler: Modular waste heat boiler, tunnel waste heat boiler, furnace-boiler integrated incineration boiler, large cavity membrane wall boiler, fire tube boiler
  • Plate heat exchanger: Fully welded pressure plate heat exchanger, high-efficiency vortex tube heat exchanger, high-efficiency spiral tube heat exchanger
  • Incineration auxiliary machine: Sludge dryer, customized burner, solid waste crusher, VOC catalyst
In what aspects are the technical advantages reflected?
We have 29 patented technologies covering incinerator structure optimization and heat recovery. Our first-class design team has mastered incinerator technology with solid theoretical foundation and rich design experience. Designers combine operation of advanced devices worldwide to carry out process and structural design with fast response times and optimization suggestions based on client requirements.
What does the service scope include?
We provide full-process services from project consultation, scheme design, equipment manufacturing to installation and commissioning, and support pressure pipeline and boiler renovation.
Are there any successful cases for reference?
We have served multiple industries including petroleum, chemical, pharmaceutical, and solid waste disposal. Typical cases include organic waste gas RTO systems and chemical waste liquid incineration projects.
How to obtain cooperation or quotation?

You can submit your needs through the official website online form, or contact directly:

Tel: +86 15606162805 ; +86 0510-87418884

Email: ruiding@rdee.com.cn

Address: Xinzhuang Industrial Concentration Zone, Yixing City, Jiangsu Province, China.

Is there any international business cooperation?
Holding independent import and export rights, we can provide equipment export and technical solution customization services for overseas customers.

Contact Us at Any Time

+86 15606162805
Xinzhuang Industrial Concentration Zone, Yixing City, Jiangsu Province, China.
Send your inquiry directly to us